Datexel

DAT 511

allpronix-datexel-511

Read More

DAT 1066

allpronix-datexel-1066

Read More

DAT 4035

allpronix-datexel-4035

Read More

DAT 4135

allpronix-datexel-4135

Read More

DAT 4530

allpronix-datexel-4530

Read More

 

DAT 511/H

 dat551_200x300 The transmitter DAT 511/H is a passive 0÷20 mA current loop isolator.The input current, variable from 0 up to 20 mA, is converted in an output current of the same value but keeping a galvanic isolation from the input circuit.The device allows the bidirectional communication of signals HART protocol compatible.The converter is a passive isolator: this means that the device employs the measurement signal to power itself, so it does not require any external power supply.

Features
  • 0÷20 mA isolated conversion
  • Hart compatible
  • No external supply required
  • 500 Vac galvanic isolation
  • Good accuracy and performance stability
  • EMC compliant – CE mark
  • Suitable for DIN rail mounting in compliance with EN 50022 and EN-50035

Read More

Back To Top


DAT 1066

dat1066_200x300 The isolated Head mounted transmitter DAT 1066(Hockey Puck) is able to execute many functions such as: measure and linearization of the temperature characteristic of RTDs sensors, conversion of a linear resistance variation, conversion of a voltage signal even coming from a potentiometer connected on its input. The device guarantees high accuracy and performances stability both in time and in temperature.The programming of the DAT 1066 is made easy by use of DATEXEL software called, PROSOFT. With PROSOFT it is possible to configure the transmitter to interface it with the most used sensors.In case of sensors with a no-standard output characteristic, it is possible to execute, via software, a “Custom” linearization (per step) to obtain an output linearized signal. A further feature that is available of alarm for signal interruption (burn-out) that allows setting the output value as high or low out of scale.The DAT 1066 has another function “Damping”, which allows the user to set a programmable filter up to 30 seconds to reduce eventual sudden variations of the input signal. 

Features
  • Configurable input for RTD, TC, mV, Resistance and Potentiometer
  • Galvanic isolation at 1500 Vac
  • 4 ÷ 20 mA configurable output on current loop
  • Configurable by Personal Computer
  • High accuracy
  • On-field reconfigurable
  • EMC compliant – CE mark
  • Suitable for DIN B in-head mounting
  • Option for DIN rail mounting in compliance with EN 50022 (DIN RAIL Option)

Read More

Back To Top


DAT 4035

dat4035_200x300 The transmitter DAT 4035 is able to execute many functions such as: measure and linearization of the temperature characteristic of RTDs sensors, conversion of a linear resistance variation, conversion of a standard active current signal, conversion of a voltage signal even coming from a potentiometer connected on its input.Moreover the DAT 4035 is able to measure and linearize the standard thermocouples with internal cold junction compensation. The device guarantees high accuracy and performances stability both in time and in temperature. The programming of the DAT 4035 is made easy by use of DATEXEL software called, PROSOFT. With PROSOFT it is possible to configure the transmitter to interface it with the most used sensors.

Features
  • Configurable input for RTD, TC, mV, V, mA, Resistance and Potentiometer
  • Galvanic isolation at 2000 Vac
  • 4 ÷ 20 mA configurable output on current loop
  • Configurable by Personal Computer
  • High accuracy
  • On-field reconfigurable
  • EMC compliant – CE mark
  • Suitable for DIN rail mounting in compliance with EN-50022 and EN50035

Read More

Back To Top


DAT 4135

dat4135_200x300 The converter DAT 4135 is able to execute many functions such as: measure and linearization of the temperature characteristic of RTDs sensors, conversion of a linear resistance variation, conversion of a standard active current signal, conversion of a voltage signal even coming from a potentiometer connected on its input. Moreover the DAT 4135 is able to measure and linearize the standard thermocouples with internal cold junction compensation. In function of programming, the measured values are converted in a current or voltage signal.The programming of the DAT 4135 is made easy by use of Datexel Software called PROSOFT, it is possible to configure the converter to interface it with the most used sensors.The 2000Vac isolation between input and power supply/output eliminates the effects of all ground loops eventually existing and allows the use of the converter in heavy environmental conditions found in industrial applications.

Features
  • Configurable input for RTD, TC, mV, V, mA, Resistance and Potentiometer
  • Galvanic isolation at 2000 Vac
  • Configurable output in current or voltage
  • Configurable by Personal Computer
  • High accuracy
  • On-field reconfigurable
  • EMC compliant – CE mark
  • Suitable for DIN rail mounting in compliance with EN-50022 and EN50035

Read More

Back To Top


DAT 4530

dat4530_200x300 The universal isolated converter DAT 4530 is able to measure and linearize voltage, current and resistance signals, potentiometers and the standard thermocouples and RTDs. In function of programming, the measured values are converted in a current or voltage signal on the two outputs. The DAT 4530 features an output contact as a trip alarm as well.The device guarantees high accuracy and performances stability both versus time and temperature.The programming is done via the dip-switch located in the window on the side of the enclosure, it is possible to select the input type and range and the output type without recalibrating the device.The 1500 Vac galvanic isolation on all ways (input, outputs and power supply) eliminates the effects of all ground loops eventually existing and allows the use of the converter in heavy environmental conditions found in industrial applications.

Features
  • Universal configurable input for: mV, Tc, RTD, Res, Potentiometer, V, mA, PTC
  • Two outputs configurable in current or voltage
  • Trip alarm
  • Configurable by dip-switch or PC
  • High accuracy
  • On-field reconfigurable
  • Galvanic isolation among all the ways
  • EMC compliant – CE mark
  • Suitable for DIN rail mounting in compliance with EN-50022 and EN-50035